Sign on

SAO/NASA ADS Astronomy Abstract Service


· Find Similar Abstracts (with default settings below)
· Electronic On-line Article (HTML)
· Table of Contents
· References in the Article
· Also-Read Articles (Reads History)
·
· Translate This Page
Title:
Charge Transfer Inefficiency effect for high-precision radial velocity measurements
Authors:
Bouchy, F.; Isambert, J.; Lovis, C.; Boisse, I.; Figueira, P.; Hébrard, G.; Pepe, F.
Affiliation:
AA(Institut d'Astrophysique de Paris, UMR 7095 CNRS, Université Pierre & Marie Curie, 98 bis Bd. Arago, 75014 Paris, France; Observatoire de Haute Provence, CNRS INSU, 04870 St. Michel l'Observatoire, France ), AB(Institut d'Astrophysique de Paris, UMR 7095 CNRS, Université Pierre & Marie Curie, 98 bis Bd. Arago, 75014 Paris, France), AC(Observatoire de Genève, Université de Genève, 51 Ch. des Maillettes, 1290 Sauverny, Switzerland), AD(Institut d'Astrophysique de Paris, UMR 7095 CNRS, Université Pierre & Marie Curie, 98 bis Bd. Arago, 75014 Paris, France), AE(Observatoire de Genève, Université de Genève, 51 Ch. des Maillettes, 1290 Sauverny, Switzerland), AF(Institut d'Astrophysique de Paris, UMR 7095 CNRS, Université Pierre & Marie Curie, 98 bis Bd. Arago, 75014 Paris, France), AG(Observatoire de Genève, Université de Genève, 51 Ch. des Maillettes, 1290 Sauverny, Switzerland)
Publication:
EAS Publications Series, Volume 37, 2009, pp.247-253
Publication Date:
00/2009
Origin:
EDP Sciences
DOI:
10.1051/eas/0937031
Bibliographic Code:
2009EAS....37..247B

Abstract

Charge Transfer Inefficiency (CTI) is a well known effect of charge-coupled devices (CCD). The charge transfer from one pixel to the next is not perfect and is quantified by the fraction of charge successfully moved (clocked) between adjacent pixels. The amplitude of this effect depends on the signal level inside the pixel. In the context of high-precision radial velocity measurements using cross-dispersed echelle spectrograph, this CTI effect on a CCD recording spectral orders may introduce associated spectral lines shifts. Indeed if the signal level recorded on the spectra is changing, the CTI amplitude will change affecting the associated centroid of all spectral lines. Such effect may introduced radial velocity shifts of several m s-1. We describe here CTI effect which is affecting the SOPHIE spectrograph installed on the 1.93-m telescope of Observatoire de Haute Provence (OHP). We calibrated the effect thanks to the Thorium-Argon lines and we applied a software correction on the spectra in order to assess the charge lost during the readout process on all pixels.
Bibtex entry for this abstract   Preferred format for this abstract (see Preferences)

   


Find Similar Abstracts:

Use: Authors
Title
Abstract Text
Return: Query Results Return    items starting with number
Query Form
Database: Astronomy
Physics
arXiv e-prints